Ultrasonic Testing
Volumetric examination using high-frequency sound to detect internal discontinuities and to measure remaining wall thickness.
- Working Principle
- A transducer introduces ultrasonic energy into the component. Reflections from interfaces and discontinuities are timed and amplitude-assessed to locate and size indications.
- Typical Indications
- Lack of fusion
- Internal cracks
- Slag inclusions
- Laminations
- Wall loss / thinning
- Applications
- Weld examination on piping and vessels
- Thickness surveys on pipework and tanks
- Plate and forging inspection
- Corrosion monitoring locations
- Equipment
- Portable digital flaw detectors and thickness gauges with appropriate probes and calibration blocks.
- Reporting
- Indication location, sizing data and thickness readings recorded against the applicable acceptance criteria.