Guided Wave / Long Range Ultrasonic Screening
Rapid screening of long pipe runs from a single test location to identify areas requiring detailed follow-up inspection.
- Working Principle
- Low-frequency guided ultrasonic waves propagate along the pipe wall. Reflections from cross-sectional changes indicate features and potential metal loss.
- Typical Indications
- Areas of metal loss
- Corrosion under insulation indications
- Cross-section changes
- Applications
- Insulated pipe runs
- Road and pipe rack crossings
- Buried and inaccessible sections where applicable
- Equipment
- Guided wave collars and instrumentation appropriate to pipe diameter and coating.
- Reporting
- Screening results with distance-referenced indications and follow-up recommendations.
Guided wave is a screening technique; indications are normally confirmed by direct inspection methods.
Request a Quote